+ Assembled by Cummins diesel engine and Leroy Somer/Stanford alternator.
+ Three filters as standard, fuel and water separator as optional.
+ Radiator and fan with safety guard.
+ Single bearing alternator IP 23, Insulation Class H.
+ Heavyduty steel as base frame and 8hrs operation base fuel tank.
+ Automatic controlpanel and 3poles circuit breaker, internal cable
+ 12V battery, battery wires. + Battery charger and float battery charger as standard supply scope.
+ Optional soundproof canopy,ATS,synchronization panel,trailers.
Diesel Genset Features P.F=0.8 3Phase |
Generating Set Performance |
|
60Hz |
Service |
|
P.R.P |
Standby |
Rated output |
kVA |
400 |
438 |
Active power output |
kW |
320 |
350 |
Rated Speed |
r.p.m |
1800 |
Standard Voltage |
V |
380/220 |
Voltage available |
V |
480/277-460/265 - 440/254-416/240-240/139-220/127-208/120 |
Perforemance data refer to Standard Reference Conditions of ISO 8528:+25ºC,100m ALT,relative humidity 30% |
|
Power reduction acc.to DIN ISO 3046 Standard values:Above 100m ALT approx.1% per 100m.Above 25ºC(77ºF) approx.4% per 10ºC(50ºF). |
|
Considering cos phi=0.8 |
Prime Mover Performance 1800 r.p.m |
SERVICE |
|
P.R.P |
Standby |
Rated output |
KW |
358 |
392 |
Manufacturer |
|
Cummins |
4 stroke Diesel Engine - Injection type |
|
Direct |
Aspiration type |
|
Turbocharged&Charge Air Cooled |
Cylinders,number and arrangement |
|
6-L |
Bore×Stroke |
mm |
140X152 |
Total Displacement |
L |
14 |
Cooling system |
|
Water |
Emission Certification |
|
STG IIIA, NRMM 3 |
Compression ratio |
|
16.3:1 |
Specific fuel consumption(P.R.P) |
L/h |
94,4 |
Specific oil consumption(at full load) |
% |
<0.1 |
Total coolant capacity |
L |
69 |
Fuel System |
Type |
CELECT(EUP) |
|
|
|
|
|
|
|
|
|
|
|
1.P.R.P. Prime Power - ISO 8528:PRIME POWER is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.10% overload available for governing purposes only. |
2.Max Standby power -ISO 3046 Fuel Stop power:Power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year ,90% load 200h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network. |
|
|
Synchronous Generator GTL |
Model |
|
K300G4 |
Poles |
num |
4 |
Winding Conections (standard) |
|
Star-serie |
Insulation |
class |
H |
Enclosure(according to IEC-34-5) |
|
IP23 |
Phases |
|
3+N |
Votage Regulators |
|
A.V.R (SX440) |
Steady voltage precision |
|
within±1.0% from no load to full loading with cosΦ=0.8-1.0 |
Alternator used by GTL Gensets meet the requirements of following Standard:BS5000,VDE0530,NEMA MG1-32,IEC34,CA C22.2-100,AS1359 |
|
Generationg Set Installation Data 1800 r.p.m |
EXHAUST SYSTEM |
Exhaust Gas Temperature at full load |
ºC |
459 |
ºF |
858,2 |
Exhaust gas flow |
Kg/h |
2385 |
Maximum allowed back pressure |
Kpa |
10 |
AIR REQUIREMENT |
Air requirement for combustion at 100% load/rated speed |
L/s |
550 |
ft3/min(CFM) |
1164,7 |
ELECTRIC STARTING SYSTEM |
Starting motor output |
kw |
N.A |
Minimum Recommended Battery Capacity-Cold Soak @ 0 °F (-18 °C) |
CCA |
900 |
Auxiliary voltage |
V |
24 |
LUBRICATION SYSTEM |
Lube oil system including sump,filters,etc. |
L |
38,6 |
Cold Start Capability |
Minimum Ambient Temp for Unaided Cold Start |
°F (°C) |
10.4(-12) |
Xiamen GTL Power System Co.,Ltd established in 2009,is a professional power generation solutions and supplier located in Xiamen of China,we engaged in the research,development, production,sales and service of Industrial diesel generator,Mobile diesel generator,Pump diesel generator,Gas generator,Air Compressor and Light towers.
The Generators we provide can be both in Open skid,weather proof and Soundproof,power range from 5 kw to 4000 kw;
The Gas generator can range from 12 kw to 1500 kw;
The Air Compressor range from 55 CFM to 1600 CFM,maximum 34.5 bar;
The Light towers were designed to offer the widest choice,multiple solutions of lamps with metal halide floodlight and LED lamp to satisfy different application,additionally,it is totally customizable.