Diesel Genset Features P.F=0.8 3Phase | ||||||||||
Generating Set Performance | 50Hz | |||||||||
Service | P.R.P | Standby | ||||||||
Rated output | kVA | 400 | 438 | |||||||
Active power output | kW | 320 | 350 | |||||||
Rated Speed | r.p.m | 1500 | ||||||||
Standard Voltage | V | 400/230 | ||||||||
Voltage available | V | 380/220 - 415/240 | ||||||||
Perforemance data refer to Standard Reference Conditions of ISO 8528:+25ºC,100m ALT,relative humidity 30% | ||||||||||
Power reduction acc.to DIN ISO 3046 Standard values:Above 100m ALT approx.1% per 100m.Above 25ºC(77ºF) approx.4% per 10ºC(50ºF). | ||||||||||
Considering cos phi=0.8 | ||||||||||
Prime Mover Performance 1500 r.p.m | ||||||||||
SERVICE | P.R.P | Standby | ||||||||
Rated output | KW | 358 | 392 | |||||||
Manufacturer | Cummins | |||||||||
4 stroke Diesel Engine - Injection type | Direct | |||||||||
Aspiration type | Turbocharged&Charge Air Cooled | |||||||||
Cylinders,number and arrangement | 6-L | |||||||||
Bore×Stroke | mm | 140X152 | ||||||||
Total Displacement | L | 14 | ||||||||
Cooling system | Water | |||||||||
Emission Certification | STG IIIA, NRMM 3 | |||||||||
Compression ratio | 16.3:1 | |||||||||
Specific fuel consumption(P.R.P) | L/h | 87,3 | ||||||||
Specific oil consumption(at full load) | % | <0.1 | ||||||||
Total coolant capacity | L | 69 | ||||||||
Fuel System | Type | CELECT(EUP) | ||||||||
P.R.P. Prime Power - ISO 8528:PRIME POWER is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.10% overload available for governing purposes only. | ||||||||||
Max Standby power -ISO 3046 Fuel Stop power:Power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year ,90% load 200h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network. | ||||||||||
Synchronous Generator GTL | ||||||||||
Model | K320G4 | |||||||||
Poles | num | 4 | ||||||||
Winding Conections (standard) | Star-serie | |||||||||
Insulation | class | H | ||||||||
Enclosure(according to IEC-34-5) | IP23 | |||||||||
Phases | 3+N | |||||||||
Votage Regulators | A.V.R (SX440) | |||||||||
Steady voltage precision | within±1.0% from no load to full loading with cosΦ=0.8-1.0 | |||||||||
Alternator used by GTL Gensets meet the requirements of following Standard:BS5000,VDE0530,NEMA MG1-32,IEC34,CA C22.2-100,AS1359 | ||||||||||
Generationg Set Installation Data 1500 r.p.m | ||||||||||
EXHAUST SYSTEM | ||||||||||
Exhaust Gas Temperature at full load | ºC | 489 | ||||||||
ºF | 912,2 | |||||||||
Exhaust gas flow | Kg/h | 2062 | ||||||||
Maximum allowed back pressure | Kpa | 10 | ||||||||
AIR REQUIREMENT | ||||||||||
Air requirement for combustion at 100% load/rated speed | L/s | 474 | ||||||||
ft3/min(CFM) | 1003,8 | |||||||||
ELECTRIC STARTING SYSTEM | ||||||||||
Starting motor output | kw | N.A | ||||||||
Minimum Recommended Battery Capacity-Cold Soak @ 0 °F (-18 °C) | CCA | 900 | ||||||||
Auxiliary voltage | V | 24 | ||||||||
LUBRICATION SYSTEM | ||||||||||
Lube oil system including sump,filters,etc. | L | 38,6 | ||||||||
Cold Start Capability | ||||||||||
Minimum Ambient Temp for Unaided Cold Start | °F (°C) | 10.4(-12) |